Links of manufacturers and/or suppliers for this section: PDF

2.1.4.a. Electrical Service Equipment                

Specifications: At least two residential service and distribution panel mockups for interconnecting PV Systems (200A and 100A main panels, with main breakers, suggested as minimum.

2.1.4.a.2.  Main Service Panel

Suggested Quantity:  Minimum of 2 (one 200A and one 100A)

Importance Rating: Essential.

Comments:  This equipment is essential for demonstrating load and supply side interconnections.

Images: click here for all images in this section.


2.1.4.b. PV Array Combiner Boxes           

Specifications: PV array source circuit combiner boxes: compact, disconnecting and standard homerun types. (Disconnecting, Arc-fault detecting and interrupting models are 2011 NEC code requirements. Recommended models include Copper Bussman BCBC-04-10P, BCBD150-12-15R and BCBS-12-30F.)

2.1.4.b.3. Combiner Box with String Monitoring

Suggested Quantity:  One per system.

Importance Rating:  Essential.

Comments:  The boxes are a key component for combining array source circuits.

Images: click here for all images in this section.


2.1.4.c. Fuses and Breakers  

Specifications:    

  • DC-rated breakers for low-voltage battery based systems2.1.4.c.1. DC Rated Breakers
  • DC rated fuses and touch-safe fuse holders for combiner boxes
  • Assortment of spare DC-rated 600V supplementary fuses for combiner boxes and inverter GFDI circuits (600 VDC: KLM-1, KLM-10, KLM-15; Solar PV Fuses 1000 VDC: 1, 10, and 15 amp)

Suggested Quantity:  4 – 6 of each

Importance Rating: Essential (for combiner boxes and battery based systems)

Comments:  Fuses and Breakers must show the required DC-rated, over-current disconnecting means to meet NEC requirements.

Images: click here for all images in this section.


2.1.4.d. Miscellaneous Electrical BOS Hardware      

Specifications: Other related service equipment, combination meter/service entrance devices, metering 2.1.4.d.1. Lightening Surge Protectionequipment, and tapping splices.

Suggested Quantity:  As needed.

Importance Rating: Essential (as needed)

Comments:  The hardware is used to demonstrate alternative PV interconnection methods.

Images: click here for all images in this section.

 

For the next 72 hours, you can download any IREC report without having to fill out this form again!

This feature requires the use of cookies in your browser. Check your browser settings if you experience any problems.